Free simulation tool
How much could curtailment be worth on your site?
The Curtailer pauses solar export the moment day-ahead price drops below a threshold you choose - so you stop paying to feed the grid. Pick a price limit to see how often that would have triggered on recent prices, and describe your plant for an estimated euro figure. No account needed.
Detailed results
Yearly
Period
Gross production
Net production
Curtailed
Rolling year
421.16 MWh
277.04 MWh
144.12 MWh (34%)
Results per month
Month
Days
Net revenue without curtailer
Net revenue with curtailer
Curtailed of produced
August 2025
20
€1.08k
€1.20k
9.32 MWh of 31.31 MWh
September 2025
30
€1.20k
€1.46k
15.01 MWh of 38.86 MWh
October 2025
31
€998.27
€1.04k
3.14 MWh of 19.16 MWh
November 2025
30
€1.12k
€1.12k
9.0 kWh of 14.08 MWh
December 2025
31
€736.18
€736.18
0.7 kWh of 10.57 MWh
January 2026
31
€1.24k
€1.24k
2.0 kWh of 13.18 MWh
February 2026
28
€1.11k
€1.11k
730.9 kWh of 16.42 MWh
March 2026
31
€1.69k
€1.85k
12.65 MWh of 42.48 MWh
April 2026
30
€391.95
€1.85k
30.71 MWh of 56.42 MWh
May 2026
31
€1.04k
€2.00k
25.32 MWh of 52.13 MWh
June 2026
30
€2.50k
€2.73k
12.94 MWh of 49.26 MWh
July 2026
31
€2.22k
€2.55k
23.17 MWh of 56.00 MWh
August 2026
11
€679.03
€847.53
11.12 MWh of 21.29 MWh
Total
365
€16.01k
€19.75k
144.12 MWh of 421.16 MWh
Close
About this simulation
Assumptions
Weather station used
De Bilt
Estimated system size
380.00 kWp
Simulation window
rolling year, 365 days with data
All simulations use weather data from De Bilt - the public simulation tool doesn't yet support other locations, so results may differ from your actual site.
Based on real KNMI 10-minute weather (irradiance and temperature) for the station above, and a pvlib/PVWatts solar-position model - not a precision instrument: it uses a simplified (isotropic) sky-diffuse model, a flat system-loss allowance, and no per-module datasheet. Savings and net revenue are both netted against your price limit - as if it were the reference rate you're paid per kWh - so a negative price contributes more than a price just below the limit.
Close
Disclaimer
This simulation tool is provided for illustrative purposes only. It is not financial, legal, or engineering advice, and Enewe BV gives no warranty as to the accuracy, completeness, or fitness for any purpose of the figures shown.
Actual solar generation, curtailment behavior, and revenue depend on your specific installation, module and inverter characteristics, shading, local grid conditions, your energy contract's terms, and future market prices - all of which may differ significantly from the assumptions used here. Historical weather and price data are not a guarantee of future results.
No rights, guarantees, or contractual commitments can be derived from any figure shown by this tool. See "About this simulation" for the specific weather station, modeling assumptions, and known limitations behind these figures.
Close
Daily curtailment statistics
« Previous day
Next day »
Interesting days:
01 May 2026 (-0.4996 €/kWh)
26 Apr 2026 (-0.4796 €/kWh)
11 May 2025 (-0.3500 €/kWh)
25 Apr 2026 (-0.2013 €/kWh)
27 Apr 2025 (-0.1899 €/kWh)
No price/weather data available for this day.
On this single day you would have profited €0.00 by curtailing 0.0 kWh of the gross 41.6 kWh production.
Amber shading marks curtailed production - intervals where the price was below your limit.
Close
Ready to put these savings to work?
Order The Curtailer for your own site - DIY install, installer install, or full service.